NSN 5925-00-479-7902
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number APL11-855-600 for national stock number 5925004797902.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-479-7902.
-
MPN or Model
APL11-855-600
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.475 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 22.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
7.400 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5950-00-084-3391 MPN 672-0018-00Power Transformer
- 5905-00-100-4002 MPN 747-0059-00Inductive Wire Wound Fixed Resistor
- 5905-00-110-0992 MPN 745-3340-000Composition Fixed Resistor
- 5985-00-135-9445 MPN 451-0219-100Radio Frequency Transmission Line Section
- 5905-00-139-1677 MPN 705-1468-730Film Fixed Resistor
- 5905-00-142-0903 MPN 705-1456-640Film Fixed Resistor
- 5950-00-157-0805 MPN 554-9780-001Electrical Coil
- 5940-00-159-0248 MPN 306-0193-000Stud Terminal
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-479-7902 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL11-855-600 | Sensata Technologies Maryland, Inc |
AM33MG6-7-5-250VAC400C15 | Eaton Corp |
APL-11-1-42-752-M | Sensata Technologies Maryland, Inc |
12MC2-203-7-5 | Sensata Technologies, Inc |
260-4042-600 | Rockwell Collins, Inc. |
260-4042-600 | Rockwell Collins, Inc. |
Stock Check