Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 9063053-7 for national stock number 5925004912184.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-491-2184.
-
MPN or Model
9063053-7
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Body Length
2.530 inches -
Body Width
0.760 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.125 inches -
Mounting Surface To Terminal End Distance
2.484 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
38.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal-magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Ultimate Trip Time Per Pole In Seconds
18.000 single location and 70.000 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 150 pct single location and 30.000 at 150 pct single location and 4.000 at 200 pct single location and 10.000 at 200 pct single location and 1.400 at 300 pct single location and 4.000 at 300 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 4820-00-010-0509 MPN 5952131Mechanical Equipment Seal Replacement Parts Kit
- 5935-00-022-9732 MPN 9986722Electrical Plug Connector
- 5935-00-192-4789 MPN 9100933Telephone Jack
- 5905-00-242-2420 MPN 10630283-305Inductive Wire Wound Fixed Resistor
- 5985-00-284-4249 MPN 8023484Waveguide Assembly
- 5935-00-331-2186 MPN 8017192Electrical Receptacle Connector
- 5905-00-474-4830 MPN 10668633-181Film Fixed Resistor
- 5985-00-481-8862 MPN 11291379Electrical Dummy Load
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-491-2184 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
9063053-7 | U S Army Aviation And Missile |
AM12MG6-38-32VDC4 | Eaton Corp |
Stock Check