NSN 5925-00-491-8921
Overload Switch
Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number EB3035 for national stock number 5925004918921.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-491-8921.
-
MPN or Model
EB3035
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-single actuator type -
Body Length
6.000 inches -
Body Width
4.125 inches -
Body Height
3.375 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.062 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.125 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations and 35.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
28.000 at 200 pct all locations and 75.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and dustproof -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
4.500 pounds -
Terminal Type And Quantity
6 compression
More from these suppliers
- 4820-00-318-9364 MPN 1791749Valve Seat
- 5905-00-333-1172 MPN 454375ITEM51Nonprecision Wire Wound Variable Resistor
- 4820-00-337-1211 MPN 40J554PC35-36Safety Relief Valve
- 5905-00-475-3975 MPN 11D3514A27Wire Wound Fixed Resistor
- 5945-00-876-1069 MPN 1739624NH11Electromagnetic Relay
- 5925-00-122-0053 MPN HQNBL2030VCircuit Breaker
- 5925-00-655-1164 MPN 452D384G23Circuit Breaker Tripper
- 5925-00-985-8344 MPN 1764704Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-491-8921 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
EB3035 | Westinghouse Electric Corp |
EHD3035 | Eaton Corporation |
6638C90G08 | Eaton Corporation |
4990D03G38 | Eaton Corporation |
EB3035 | Eaton Corporation |