1-321-802-5889

NSN 5925-00-497-9659

Overload Switch

About this product

Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.

Manufacturer part number BQ3B040 for national stock number 5925004979659.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-497-9659.

  • MPN or Model

    BQ3B040

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.5 lb
  • Body Style
    Multipole-multiple actuator type
  • Body Length
    Between 3.735 inches and 3.765 inches
  • Body Width
    Between 2.985 inches and 3.015 inches
  • Body Height
    Between 2.327 inches and 2.515 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Width
    Between 0.985 inches and 1.015 inches
  • Unthreaded Mounting Hole Diameter
    0.219 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    Between 0.173 inches and 0.203 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    3 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Maximum Continuous Load Current Rating Per Pole
    40.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    240.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    5000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations and time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    140.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    3 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At each pole
  • External Actuator Linkage Arrangement
    One, two, and three linked
  • Trip Delay Time In Seconds Per Rated Continuous Current
    360.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    Fungus proof
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    3 quick disconnect, male and 3 tab, solder lug
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-497-9659 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925004979659

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
BQ3B040 Spd Electrical Systems, Inc
10937535 U S Army Tank Automotive Command
BQ3B040 Siemens Energy And Automation Inc
Stock Check