NSN 5925-00-501-7677
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number AM1510MG3-15-115-60HZ-1 for national stock number 5925005017677.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-501-7677.
-
MPN or Model
AM1510MG3-15-115-60HZ-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
3.719 inches -
Body Width
0.990 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
28.000 at 200 pct single location and 105.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and explosion resistant and hermetically sealed -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-081-1005 MPN SM3-3-110V60CPS57Circuit Breaker
- 5925-00-150-1072 MPN JA3-C3-30-2Circuit Breaker
- 5925-00-163-3658 MPN AM17-30-208VAC60C55Circuit Breaker
- 5925-00-238-5170 MPN 72-327-10MG6Circuit Breaker
- 5925-00-299-7809 MPN 50-309MG3-30Circuit Breaker
- 5925-00-449-0047 MPN AM12MG3-25-32DC5Circuit Breaker
- 5925-00-752-3176 MPN AM444CSKMG6-7-5-240-14-400Circuit Breaker
- 5925-00-853-1995 MPN AM17MG3-15-120-54-400Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-501-7677 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM1510MG3-15-115-60HZ-1 | Eaton Corp |
AM1510M6-15A115V60HZ | Eaton Corp |