NSN 5925-00-511-4942
Overload Switch
Handle color with on-off markings black with white markings.
Manufacturer part number UPG1-1-6-1-102-01 for national stock number 5925005114942.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-511-4942.
-
MPN or Model
UPG1-1-6-1-102-01
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.000 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
1000.0 single location -
Ultimate Trip Time Per Pole In Seconds
0.003 single location and 0.040 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 at 125 pct single location and 12.000 at 125 pct single location and 0.350 at 150 pct single location and 4.000 at 150 pct single location and 0.130 at 200 pct single location and 1.300 at 200 pct single location and 0.030 at 400 pct single location and 0.200 at 400 pct single location and 0.003 at 1000 pct single location and 0.040 at 1000 pct single location and 0.008 at 600 pct single location and 0.130 at 600 pct single location and 0.003 at 800 pct single location and 0.070 at 800 pct single location -
Inclosure Protection Type For Which Designed
Moisture resistant and vibrationproof and salt spray proof -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5945-00-900-5170 MPN 2307Electronic Chopper
- 5925-00-005-3176 MPN UPL-111-1-69-502-MCircuit Breaker
- 5925-00-429-1657 MPN APL111-1R0-42-103-MCircuit Breaker
- 5925-00-925-3921 MPN 520I202Circuit Breaker
- 5925-01-037-6878 MPN AP12-1-6-1-802Circuit Breaker
- 5925-01-075-7140 MPN APL111-3REC2-4613-18Circuit Breaker
- 5925-01-108-8047 MPN APL-111-6588-7Circuit Breaker
- 5925-01-131-0199 MPN APGN-666-1REC3-7026-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-511-4942 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPG1-1-6-1-102-01 | Sensata Technologies Maryland, Inc |