NSN 5925-00-513-2849
Overload Switch
Single pole type body style, plastic case material, 1 poles, arc quenching method: magnetic blowout.
Manufacturer part number KS20684L1 for national stock number 5925005132849.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-513-2849.
-
MPN or Model
KS20684L1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.650 at 200 pct single location and 9.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Unpackaged Unit Weight
3.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5945-00-188-6040 MPN D161973-1Electromagnetic Relay
- 5935-00-222-8213 MPN G377496-1Telephone Jack
- 5950-00-246-5260 MPN B0170016Power Transformer
- 5950-00-346-3608 MPN GA51964Pulse Transformer
- 5945-00-503-6251 MPN Y74RELAYElectromagnetic Relay
- 5930-00-758-5416 MPN 321009Switch Cap
- 5905-01-089-9482 MPN KS20616L1A750Film Fixed Resistor
- 5930-01-147-5914 MPN P29E751Push Button
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-513-2849 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
KS20684L1 | Lucent Technologies Inc |
KS20684L1 | American Telephone And Telegraph Co |
70-396-1MG6 | Eaton Corp |
KS20684L1 | Lucent Technologies Inc |