NSN 5925-00-549-8937
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number AA55571/05-001 for national stock number 5925005498937.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-549-8937.
-
MPN or Model
AA55571/05-001
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Overall Length
2.172 inches -
Body Width
0.703 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.031 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.344 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 ac single location and 575.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push button -
Actuator Function
Reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 50.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5940-00-082-5002 MPN A-A-59126/16Stud Terminal
- 5975-00-239-0352 MPN A-A-50563Conduit Outlet
- 5940-00-829-1458 MPN AA59126/30Stud Terminal
- 5940-01-015-1272 MPN AA59126/09904Stud Terminal
- 5940-01-200-7765 MPN AA59126/1215Stud Terminal
- 5935-01-323-6814 MPN A-A-55463-05Electrical Receptacle Connector Body
- 6145-01-212-4355 MPN A-A-59544Electrical Wire
- 6145-01-273-0076 MPN USE06CE2/10XPNJElectrical Power Cable
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-549-8937 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AA55571/05-001 | Federal Commercial Item Description |
PSA10 | Sensata Technologies, Inc |