NSN 5925-00-556-3416
Overload Switch
Plastic case material, moderately rugged fragility factor, 2 poles, arc quenching method: magnetic blowout.
Manufacturer part number XAM33MG3 for national stock number 5925005563416.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-556-3416.
-
MPN or Model
XAM33MG3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
2.500 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
117.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 1.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5945-00-681-9736 MPN FM2-522XAXElectromagnetic Relay
- 5925-00-035-4126 MPN AM1C3A10-2Circuit Breaker
- 5925-00-230-7629 MPN AM333MG6-7-5-250VAC60C4Circuit Breaker
- 5925-00-584-6242 MPN AM3A3A20-2Circuit Breaker
- 5925-00-615-8335 MPN SM3-3-50DC58Circuit Breaker
- 5925-00-615-8376 MPN SM3-25A50VDC28Circuit Breaker
- 5925-00-811-7958 MPN AM12M6-115VAC10AMP4Circuit Breaker
- 5925-01-032-5003 MPN JA1-Z269-5Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-556-3416 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
XAM33MG3 | Eaton Corp |
AM33MG6-35-117VAC60C4 | Eaton Corp |