NSN 5925-00-581-3664
Overload Switch
Metal case material, 2 poles, 640.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 355.0 dc all locations.
Manufacturer part number MILC17587 for national stock number 5925005813664.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-581-3664.
-
MPN or Model
MILC17587
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Metal -
Unthreaded Mounting Hole Diameter
0.562 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
8 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
640.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
355.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 all locations -
Reset Method
Automatic -
Manual Actuator Type And Quantity
1 rotary -
Terminal Type And Quantity
4 bus bar -
Nondefinitive Specification/std Data
Acb640 type
More from these suppliers
- 5930-00-507-5953 MPN S1151503-DRotary Switch
- 5950-00-646-0346 MPN 37J280PC50Electrical Coil
- 5950-01-200-3885 MPN 243A923G04Power Transformer
- 5950-01-287-3550 MPN 1F0892Power Transformer
- 5925-00-617-8312 MPN 908D568PC1Circuit Breaker Subassembly
- 5925-00-812-0625 MPN S035Y6313Circuit Breaker
- 5925-00-948-0046 MPN S457D456G22Circuit Breaker Tripper
- 5925-01-227-2562 MPN 445D735SUB10Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-581-3664 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
MILC17587 | Military Specifications |
405D201 | Westinghouse Electric Corp |
405D201 | Westinghouse Electric Corp |
405D201SUB2 | Westinghouse Electric Corp |
S022Y6927B1 | Westinghouse Electric Corp |
S022Y7880B1 | Westinghouse Electric Corp |
S023Y1005B1 | Westinghouse Electric Corp |