NSN 5925-00-620-5854
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, thready qty per inch (tpi): 20.
Manufacturer part number PP400-6-4 for national stock number 5925006205854.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-620-5854.
-
MPN or Model
PP400-6-4
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
5.000 inches -
Body Width
4.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.625 inches -
Center To Center Distance Between Terminals Parallel To Width
1.688 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.312 inches -
Mounting Surface To Terminal End Distance
4.625 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
2 threaded hole -
Thready Qty Per Inch (tpi)
20 -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations and 50.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations and 125.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations and 5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Thread Size
0.250 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct all locations and 210.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 compression
More from these suppliers
- 5950-00-205-9910 MPN 9T56Y2379DAPower Transformer
- 5950-00-399-0449 MPN 11K1840ITEM8AElectrical Coil
- 5905-01-126-9324 MPN 68A7041A8127F2Inductive Wire Wound Fixed Resistor
- 5930-01-166-7143 MPN 10AA044Rotary Switch
- 5950-01-212-9660 MPN 7053F28 PIECE 47Power Transformer
- 5925-01-330-9208 MPN TB13040BWE05Circuit Breaker
- 6105-01-359-3757 MPN 5K215BL9074HAlternating Current Motor
- 5930-00-264-5661 MPN TKMAYT3Switch Handle
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-620-5854 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
PP400-6-4 | Bauer, Inc. |
6319482G6L | General Electric Co |
TN231050 | General Electric Co |