NSN 5925-00-646-8003
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 711599-130 for national stock number 5925006468003.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-646-8003.
-
MPN or Model
711599-130
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.611 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location and 10.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-200-9476 MPN AM12MG3-5-28-5Circuit Breaker
- 5925-00-279-1035 MPN AM1515-10-120-2MCircuit Breaker
- 5925-00-308-7155 MPN AM12HKMG6-25-125VAC60C4Circuit Breaker
- 5925-00-572-6118 MPN 50VAC60C3Circuit Breaker
- 5925-00-804-5814 MPN AM13HKMG3-1.5-115-4-60Circuit Breaker
- 5925-00-940-8088 MPN AM12MG6-30A32VDCCURVE4Circuit Breaker
- 5925-00-945-5463 MPN HE1-C3-1-5-240VAC2-400HZCircuit Breaker
- 5925-00-964-4895 MPN AM444MG6-0-3-250VAC400C14Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-646-8003 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
711599-130 | Raytheon Company |
AM13HKMG6-5-115VAC60C4 | Eaton Corp |
AM13HKMG3-5-115-4-60 | Eaton Corp |