NSN 5925-00-701-5045
Overload Switch
Metal case material, 3 poles, 3200.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 500.0 ac all locations.
Manufacturer part number 701363-705144 for national stock number 5925007015045.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-701-5045.
-
MPN or Model
701363-705144
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1312 lb -
Case Material
Metal -
Unthreaded Mounting Hole Diameter
0.750 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
8 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
3200.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Reset Method
Electric -
Main Contact Tripping Mechanism Type
Trip free -
Auxiliary Switch Function And Quantity
2 alarm -
Reset Actuator Voltage Rating And Type In Volts
115.0 ac -
Inclosure Protection Type For Which Designed
Shockproof -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5985-00-630-8047 MPN 493053-1REVJRadio Frequency Transmission Line Section
- 5950-01-198-6182 MPN G103E446Electrical Coil
- 5950-01-353-7401 MPN 706378T02Electrical Coil
- 5930-01-363-9379 MPN ETN9718Sensitive Switch
- 5930-01-432-2151 MPN 741298-ASwitch Latch
- 5905-01-494-9032 MPN 712100PC247Inductive Wire Wound Fixed Resistor
- 5940-01-591-4846 MPN 198749-A00Lug Terminal
- 5930-01-604-8300 MPN 120796-A00Dust And Moisture Seal Boot
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-701-5045 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
701363-705144 | Spd Electrical Systems, Inc |
701363-711715 | Henderson Engineering Co Inc |
Stock Check
![](/public/images/partscage_shelf3.png)