1-321-802-5889

NSN 5925-00-729-0575

Overload Switch

About this product

Single pole type body style, plastic case material, 1 poles, arc quenching method: air.

Manufacturer part number CVC2523-10 for national stock number 5925007290575.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-729-0575.

  • MPN or Model

    CVC2523-10

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Single pole type
  • Bushing Length
    0.250 inches
  • Body Length
    1.094 inches
  • Body Width
    0.750 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    0.703 inches
  • Mounting Surface To Terminal End Distance
    1.812 inches
  • Pole Quantity
    1
  • Arc Quenching Method
    Air
  • Mounting Facility Type And Quantity
    1 threaded bushing
  • Storage Type
    General purpose warehouse
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    10.0 amperes ac single location and 10.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    120.0 ac single location and 30.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    3500.0 ac single location and 6000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Thermal single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    138.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 push-pull
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.469 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    15.000 at 200 pct single location and 55.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Explosion proof
  • Trip Release Ambient Tempurature Rating
    25.0 degrees celsius single location
  • Frequency In Hertz
    400.0 single location
  • Precious Material And Location
    Contact surfaces silver
  • Precious Material
    Silver
  • Thread Series Designator
    Uns
  • Terminal Type And Quantity
    2 tab w/screw
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-729-0575 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925007290575

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
CVC2523-10 Triumph Aerostructures, Llc
CVC2523-10 Labinal, Llc
CVC2523-10 Labinal, Llc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.