NSN 5925-00-759-0906
Overload Switch
Multipole-single actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number HM2-B3-5-50DC-2 for national stock number 5925007590906.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-759-0906.
-
MPN or Model
HM2-B3-5-50DC-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.365 inches and 0.385 inches -
Body Length
Between 1.552 inches and 1.572 inches -
Body Width
Between 1.271 inches and 1.291 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.865 inches and 0.885 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.615 inches and 0.635 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.690 inches and 1.710 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.120 at 200 pct all locations and 0.750 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5925-00-170-4081 MPN GB3-A3-0.5-1Circuit Breaker
- 5925-00-192-3208 MPN AM12-1-125VAC50-60-5Circuit Breaker
- 5925-00-915-8865 MPN AM333MG6-250V60-2A4Circuit Breaker
- 5925-00-927-5434 MPN 53-136-2MG3Circuit Breaker
- 5925-00-932-3027 MPN 0111-10-250-60-3Circuit Breaker
- 5925-01-040-7980 MPN 410AS128Circuit Breaker
- 5925-01-073-8952 MPN 72-143-17Circuit Breaker
- 5925-01-096-4665 MPN SM333GF2GCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-759-0906 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
HM2-B3-5-50DC-2 | Eaton Corp |
HE2-B3-5-50DC-2 | Eaton Corp |
SM33-5DC2 | Eaton Corp |
Stock Check