NSN 5925-00-760-0956
Overload Switch
Multipole-single actuator type body style, metal case material, single pole, double throw switch contact arrangement, pole quantity: 2.
Manufacturer part number 2638051-30 for national stock number 5925007600956.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-760-0956.
-
MPN or Model
2638051-30
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Multipole-single actuator type -
Bushing Length
0.330 inches -
Body Length
1.562 inches -
Body Width
1.281 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Switch Contact Arrangement
Single pole, double throw -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
0.200 all locations and 7.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Auxiliary Switch Function And Quantity
1 control -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 at 200 pct all locations and 0.950 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed -
Switch Terminal Type
Wire hook -
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5930-00-044-1882 MPN 1569784Rotary Switch Section
- 5935-00-071-9920 MPN 1987052Electrical Connector Cover
- 5950-00-076-7829 MPN 2493276-2Radio Frequency Coil
- 5940-00-173-8435 MPN 209469PC6Lug Terminal
- 5985-00-195-1796 MPN 2995353Variable Attenuator
- 5975-00-210-4652 MPN 417379PC9Cable Marker Sleeve
- 5950-00-230-1626 MPN 2922779Power Transformer
- 5940-00-241-4905 MPN 17B78150-3279Terminal Board
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-760-0956 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2638051-30 | Navair And Navsea Managed |
T505-004-230 | Lockheed Martin Librascope |