1-321-802-5889

NSN 5925-00-790-3799

Overload Switch

About this product

Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.

Manufacturer part number 711570-36REVC for national stock number 5925007903799.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-790-3799.

  • MPN or Model

    711570-36REVC

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Single pole type
  • Body Length
    Between 2.485 inches and 2.515 inches
  • Body Width
    Between 0.735 inches and 0.765 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    Between 1.925 inches and 1.955 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    Between 2.047 inches and 2.077 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Fragility Factor
    Moderately rugged
  • Boss Height
    Between 0.125 inches and 0.155 inches
  • Mounting Surface To Terminal End Distance
    Between 2.775 inches and 2.955 inches
  • Pole Quantity
    1
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    2 threaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    10.0 amperes ac single location and 10.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    250.0 ac single location and 50.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    1000.0 ac single location and 2000.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.138 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    3.000 at 200 pct single location and 10.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Shock resistant and vibration resistant and moisture resistant and salt spray proof and fungus resistant
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    5.0 ac and 1.0 dc
  • Switch Voltage Rating And Type In Volts
    115.0 ac and 50.0 dc
  • Frequency In Hertz
    60.0 single location
  • Unpackaged Unit Weight
    0.312 pounds
  • Test Data Document
    05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
  • Thread Series Designator
    Unc
  • Terminal Type And Quantity
    2 threaded stud
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-790-3799 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925007903799

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
711570-36REVC Raytheon Company
711570-36REVC Raytheon Company
70-132-17MG6-10-50-250VAC4 Eaton Corp
AM12HKMG3-10-0-50-250VAC4 Eaton Corp
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.