NSN 5925-00-804-3451
Overload Switch
Plastic case material, single pole, double throw switch contact arrangement, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number L219716-12 for national stock number 5925008043451.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-804-3451.
-
MPN or Model
L219716-12
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
200.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 at 200 pct single location and 12.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and explosion resistant -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5930-00-548-5613 MPN C243190Rotary Switch Section
- 5950-00-572-0314 MPN N216332-4Radio Frequency Coil
- 5950-00-686-6490 MPN L285397-1Power Transformer
- 5930-00-789-1751 MPN C218600-18Rotary Switch
- 5950-00-942-4452 MPN L665047-1Radio Frequency Coil
- 5950-00-518-1053 MPN A27058Power Transformer
- 5935-00-221-3226 MPN AC56586-1Electrical Plug Connector
- 5950-00-246-5227 MPN A1716Reactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-804-3451 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
L219716-12 | Raytheon Company |
70-123-12MG3 | Eaton Corp |