NSN 5925-00-804-3480
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 1.
Manufacturer part number L219716-3 for national stock number 5925008043480.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-804-3480.
-
MPN or Model
L219716-3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.997 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Ultimate Trip Time Per Pole In Seconds
70.000 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 at 200 pct single location and 3.500 at 300 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and explosion resistant -
Switch Terminal Type
Turret -
Switch Current Rating And Type In Amps
5.0 ac -
Switch Voltage Rating And Type In Volts
115.0 ac -
Frequency In Hertz
60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5905-00-192-9131 MPN L72473BNonprecision Nonwire Wound Variable Resistor
- 5935-00-204-9183 MPN C223284-1Electrical Plug Connector
- 5950-00-226-7056 MPN 2088861-0701Audio Frequency Transformer
- 5945-00-433-5822 MPN 2054147-0705Meter Movement Relay
- 5935-00-470-0309 MPN 4049322-0701Electrical Plug Connector
- 5950-00-538-4999 MPN L291842-1Radio Frequency Transformer
- 5950-01-189-7610 MPN XR-1076Reactor
- 5905-01-193-1898 MPN 2088181-0035Nonprecision Nonwire Wound Variable Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-804-3480 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
L219716-3 | Raytheon Company |
70-123-3MG3 | Eaton Corp |