NSN 5925-00-809-2335
Overload Switch
Plastic case material, 3 poles, 20.0 amperes ac all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 600.0 ac all locations.
Manufacturer part number 999320 for national stock number 5925008092335.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-809-2335.
-
MPN or Model
999320
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.175 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Trip Delay Time In Seconds Per Rated Continuous Current
240.000 at 150 pct all locations and 50.000 at 200 pct all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 eyelet
More from these suppliers
- 5925-01-157-9795 MPN FAL34045-1021Circuit Breaker
- 5925-01-574-6532 MPN FA14070Circuit Breaker
- 5930-01-512-9366 MPN 9421-ND1Interlock Switch
- 5925-01-604-8813 MPN HDL36020C-AABESOMACircuit Breaker
- 6110-01-365-1497 MPN 8536SCG3V03Motor Starter
- 6110-01-445-6042 MPN 80420-302-52Electric Power Resetting Device
- 6110-01-449-1473 MPN LC1-K-09004-B7Magnetic Contactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-809-2335 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
999320 | Square D Co |
999220 | Schneider Electric Usa, Inc. |
Stock Check
![](/public/images/partscage_shelf3.png)