1-321-802-5889

NSN 5925-00-819-1098

Overload Switch

About this product

Designed for use with klixon 3mc circuit breakers.

Manufacturer part number 7236-1-175 for national stock number 5925008191098.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-819-1098.

  • MPN or Model

    7236-1-175

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    0.9 lb
  • Body Style
    Rectangular dimensional envelope
  • Overall Length
    4.688 inches
  • Overall Height
    1.675 inches
  • Overall Width
    2.578 inches
  • Case Material
    Plastic
  • Unthreaded Mounting Hole Diameter
    0.203 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Fragility Factor
    Moderately rugged
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    2 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    175.0 amperes ac single location
  • Operating Voltage Type And Rating Per Pole In Volts
    120.0 ac single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    1000.0 ac single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Thermal single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    138.0 single location
  • Reset Method
    Automatic
  • Auxiliary Switch Function And Quantity
    1 control
  • Internal Trip Release Configuration
    Series trip single location
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    10.000 at 200 pct single location and 200.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    General purpose
  • Trip Release Ambient Tempurature Rating
    77.0 degrees fahrenheit single location
  • Switch Terminal Type
    Screw
  • Switch Current Rating And Type In Amps
    10.0 dc
  • Switch Voltage Rating And Type In Volts
    28.0 dc
  • Frequency In Hertz
    60.0 single location
  • Unpackaged Unit Weight
    15.000 ounces
  • Terminal Type And Quantity
    2 threaded stud
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-819-1098 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925008191098

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
7236-1-175 Sensata Technologies, Inc
7236-1-175 Texas Instruments Inc
D7236-1-175 Sensata Technologies, Inc
11069756 U S Army Aviation And Missile
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.