NSN 5925-00-829-2456
Overload Switch
Multipole-single actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number SM333-1-5-240VAC400C2 for national stock number 5925008292456.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-829-2456.
-
MPN or Model
SM333-1-5-240VAC400C2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.375 inches -
Body Length
1.500 inches -
Body Width
1.875 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.875 inches -
Center To Center Distance Between Terminals Parallel To Width
0.625 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.780 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Ultimate Trip Time Per Pole In Seconds
0.800 all locations and 5.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct all locations and 0.690 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and explosion resistant and hermetically sealed -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook
More from these suppliers
- 5925-00-487-6527 MPN AM333MG6-20-120VAC400C15Circuit Breaker
- 5925-00-622-0341 MPN JL1A2-8-3Circuit Breaker
- 5925-00-816-9929 MPN XAM333-45-208VAC60-1Circuit Breaker
- 5925-00-845-9780 MPN SM3-10CURVE57-120VACCircuit Breaker
- 5925-00-959-6075 MPN SM3-10-50VDC57Circuit Breaker
- 5925-01-025-7007 MPN HB3Z1-91Circuit Breaker
- 5925-01-048-1016 MPN AM3-C3-A-5-2Circuit Breaker
- 5925-01-070-6886 MPN JA2-A3-20-10Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-829-2456 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SM333-1-5-240VAC400C2 | Eaton Corp |
AP112-1-4-1-152 | Sensata Technologies Maryland, Inc |
HE3C3-1-5-240AC400HZ2 | Eaton Corp |