NSN 5925-00-836-4574
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 1.
Manufacturer part number AM12HKMG3-10-0-23 for national stock number 5925008364574.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-836-4574.
-
MPN or Model
AM12HKMG3-10-0-23
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.750 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct single location and 0.500 at 200 pct single location -
Inclosure Protection Type For Which Designed
Explosion resistant and fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Unpackaged Unit Weight
4.250 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5945-00-781-3399 MPN C376-3Thermal Relay
- 5925-00-078-9566 MPN PAM1510NKMG313AMP200VDCCircuit Breaker
- 5925-00-081-9135 MPN 70-667MG3-24Circuit Breaker
- 5925-00-161-9146 MPN JA1-A3-A-5-2Circuit Breaker
- 5925-00-186-0765 MPN 70-123-10MG6Circuit Breaker
- 5925-00-459-9002 MPN 53-168-5MG3Circuit Breaker
- 5925-00-552-6431 MPN 70-574JMG3Circuit Breaker
- 5925-00-966-5836 MPN 72-169-2MG6Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-836-4574 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM12HKMG3-10-0-23 | Eaton Corp |