NSN 5925-00-856-7894
Overload Switch
Plastic case material, single pole, double throw switch contact arrangement, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 711562-11 for national stock number 5925008567894.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-856-7894.
-
MPN or Model
711562-11
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
Between 3.709 inches and 3.729 inches -
Body Width
Between 3.042 inches and 3.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and 1.041 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and 1.041 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
Between 3.177 inches and 3.301 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
3.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
0.350 at 200 pct all locations and 1.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
1.770 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5950-00-051-2179 MPN 5025-948Radio Frequency Coil
- 5985-00-110-0333 MPN 723850-54Fixed Attenuator
- 5905-00-113-7346 MPN 4171306-419Composition Fixed Resistor
- 5905-00-185-8510 MPN 4171300-6Composition Fixed Resistor
- 5905-00-247-8737 MPN 4171306-465Composition Fixed Resistor
- 5905-00-403-3156 MPN 4171594-22Film Fixed Resistor
- 5935-00-449-0187 MPN 1545663-1Electrical Connector Set
- 5940-00-557-9517 MPN 722259-028Stud Terminal
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-856-7894 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
711562-11 | Raytheon Company |
711562-11 | Raytheon Company |
53-114-9MG3 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)