NSN 5925-00-869-1630
Overload Switch
Rectangular dimensional envelope body style, plastic case material, 2 poles, storage type: general purpose warehouse.
Manufacturer part number NEF421015R for national stock number 5925008691630.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-869-1630.
-
MPN or Model
NEF421015R
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Rectangular dimensional envelope -
Overall Length
9.375 inches -
Overall Height
4.531 inches -
Overall Width
2.750 inches -
Case Material
Plastic -
Unthreaded Mounting Hole Diameter
0.190 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations and 15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 rotary -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 at 200 pct all locations and 35.000 at 200 pct all locations -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 compression
More from these suppliers
- 6110-01-201-9287 MPN DA83-01-069C-080Motor Starter
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-869-1630 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
NEF421015R | E C C Spares & Services Electro Work |
NEF421015R | Challenger Electrical Equipment Corp |