NSN 5925-00-871-6476
Overload Switch
Multipole-single actuator type body style, metal case material, at 3 oclock and at 9 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number AP112-1-61-502 for national stock number 5925008716476.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-871-6476.
-
MPN or Model
AP112-1-61-502
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.332 inches and 0.380 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.594 inches and 0.656 inches -
Nonturn Device Location
At 3 oclock and at 9 oclock -
Nonturn Device Radius
Between 0.594 inches and 0.656 inches -
Nonturn Device Length
Between 0.099 inches and 0.161 inches -
Nonturn Device Diameter
Between 0.219 inches and 0.281 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations and 5.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 at 200 pct all locations and 0.950 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and hermetically sealed -
Frequency In Hertz
400.0 all locations -
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook -
Specification Data
81349-mil-c-39019/5 government specification
More from these suppliers
- 5940-00-057-7415 MPN 3249862Feedthru Terminal
- 5945-00-071-3636 MPN 695132Electromagnetic Relay
- 5905-00-071-5874 MPN 1851781PC1Nonprecision Wire Wound Variable Resistor
- 5985-00-073-3759 MPN 2269739Directional Coupler
- 5940-00-173-8494 MPN 188208PC9Lug Terminal
- 5935-00-231-1114 MPN 2534839-8Electrical Receptacle Connector
- 5940-00-238-6212 MPN 2864371-1Terminal Board
- 5950-00-238-6825 MPN 10001-2422574Power Transformer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-871-6476 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP112-1-61-502 | Sensata Technologies Maryland, Inc |
SM333-5-230-400-2 | Eaton Corp |
SM333-5-230-400-58 | Eaton Corp |
SM333-5-230VAC400C2 | Eaton Corp |
SM333-5-240-400-2 | Eaton Corp |
SM333-5-240VAC400C2 | Eaton Corp |
SM333-5-400-2 | Eaton Corp |
M39012/05-230 | Military Specifications |
M39019-5-230 | Military Specifications |
M3909/05-230 | Military Specifications |
M39019+5+45 | Military Specifications |
M39019-5-47 | Military Specifications |
888997-3004 | Litton Systems Inc. Div Navigation |
M39019/05-230 | Military Specifications |
MIL-PRF-39019/5 | Military Specifications |
990C963H04 | Northrop Grumman Systems Corporation |
2291621-1 | Lockheed Martin Corporation |
2291621-1 | Navair And Navsea Managed |
620A502SGL | Sensata Technologies Maryland, Inc |
720A502SGL | Sensata Technologies Maryland, Inc |
AP112F6-502 | Sensata Technologies Maryland, Inc |
165040-2 | Raytheon Company |
10022975-107 | Honeywell International Inc. |
2907798-1 | Naval Sea Systems Command |
MIL-C-39019/5 | Military Specifications |
Stock Check
- NS: 7
- NE: 6