NSN 5925-00-883-8575
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 260-2987-00 for national stock number 5925008838575.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-883-8575.
-
MPN or Model
260-2987-00
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.2 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 3.709 inches and 3.729 inches -
Body Width
Between 3.042 inches and 3.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and 1.041 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and 1.041 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
12.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 at 200 pct all locations and 0.650 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5945-00-060-1365 MPN 974-0791-000Electromagnetic Relay
- 5930-00-086-9851 MPN 259-1455-000Rotary Switch
- 5905-00-088-0723 MPN 714-1940-000Composition Fixed Resistor
- 5905-00-147-4102 MPN 705-3162-720Film Fixed Resistor
- 5950-00-194-3387 MPN 559-1740-001Power Transformer
- 5935-00-195-3387 MPN 780-0523-001Electrical Receptacle Connector
- 5935-00-197-4331 MPN 366-2060-00Electrical Receptacle Connector
- 4820-00-214-9996 MPN 332-2718-010Fluid Pressure Regulating Valve
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-883-8575 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-2987-00 | Rockwell Collins, Inc. |
3XAM1516MG3-12-120AC16-400CPS | Eaton Corp |
Stock Check