1-321-802-5889

NSN 5925-00-895-3649

Overload Switch

About this product

Plastic case material, 1 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 200.0 milliamperes ac single location.

Manufacturer part number SM3-0.2,115V,DELAY CURVE 1 for national stock number 5925008953649.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-895-3649.

  • MPN or Model

    SM3-0.2,115V,DELAY CURVE 1

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Case Material
    Plastic
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    1 threaded bushing
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    200.0 milliamperes ac single location
  • Operating Voltage Type And Rating Per Pole In Volts
    200.0 ac single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    750.0 ac single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.375 inches
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.800 at 200 pct single location and 1.000 at 200 pct single location
  • Inclosure Protection Type For Which Designed
    Weatherproof
  • Frequency In Hertz
    60.0 single location
  • Thread Series Designator
    Unef
  • Terminal Type And Quantity
    2 tab, solder lug
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-895-3649 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925008953649

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
SM3-0.2,115V,DELAY CURVE 1 Eaton Corp
SM3-0.2-115-1 Eaton Corp
G327165-2 American Telephone And Telegraph Co
Stock Check