1-321-802-5889

NSN 5925-00-899-8472

Overload Switch

About this product

Multipole-single actuator type body style, plastic case material, 3 poles, storage type: general purpose warehouse.

Manufacturer part number TFJ236Y225WL for national stock number 5925008998472.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-899-8472.

  • MPN or Model

    TFJ236Y225WL

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    8 lb
  • Body Style
    Multipole-single actuator type
  • Body Length
    10.125 inches
  • Body Width
    8.250 inches
  • Body Height
    4.062 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    9.125 inches
  • Center To Center Distance Between Terminals Parallel To Width
    2.750 inches
  • Unthreaded Mounting Hole Diameter
    0.203 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    7.750 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    2.750 inches
  • Boss Height
    0.250 inches
  • Pole Quantity
    3
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    225.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    600.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    14000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    150.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Nontrip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Trip Delay Time In Seconds Per Rated Continuous Current
    100.000 at 200 pct all locations and 275.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    General purpose
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    6 compression
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-899-8472 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925008998472

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
TFJ236Y225WL General Electric Co
TFJ236Y225 General Electric Co
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.