NSN 5925-00-930-2265
Overload Switch
Multipole-single actuator type body style, metal case material, double pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number THKMTKM11-836700 for national stock number 5925009302265.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-930-2265.
-
MPN or Model
THKMTKM11-836700
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
Between 15.470 inches and 15.530 inches -
Body Width
Between 8.220 inches and 8.280 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 11.590 inches and 11.650 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 2.720 inches and 2.780 inches -
Unthreaded Mounting Hole Diameter
Between 0.340 inches and 0.400 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 14.220 inches and 14.280 inches -
Switch Contact Arrangement
Double pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 2.720 inches and 2.780 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.350 inches and 0.410 inches -
Mounting Surface To Terminal End Distance
Between 10.970 inches and 11.030 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
Adjustable trip release -
Maximum Continuous Load Current Rating Per Pole
700.0 amperes ac all locations and 700.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 125.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations and 65000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 control -
Adjustable Trip Setting Current Range Per Pole In Amps
+2100.0/+7000.0 ac all locations and +2100.0/+7000.0 dc all locations -
Switch Location And Position Designation
Internal at pole three -
Inclosure Protection Type For Which Designed
Hermetically sealed and weatherproof -
Trip Release Ambient Tempurature Rating
40.0 degrees celsius all locations -
Switch Terminal Type
Wire lead -
Switch Current Rating And Type In Amps
6.0 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
600.0 ac and 125.0 dc -
Frequency In Hertz
60.0 all locations -
Precious Material And Location
Contacts silver -
Precious Material
Silver -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-042-6502 MPN 9157522Film Fixed Resistor
- 4820-00-106-7365 MPN 10162235Check Valve
- 5905-00-122-4961 MPN 9986741-14Inductive Wire Wound Fixed Resistor
- 5905-00-187-3506 MPN 10605775-11Nonprecision Wire Wound Variable Resistor
- 5935-00-232-2720 MPN 10670776Electrical Receptacle Connector
- 5930-00-232-8466 MPN 10667825-2Rotary Switch
- 5975-00-281-0049 MPN 10338767Electrical Box Connector
- 5935-00-348-5709 MPN MIS-12833/4Electrical Receptacle Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-930-2265 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
THKMTKM11-836700 | General Electric Co |
9995643-2 | U S Army Aviation And Missile |
9995643-2 | General Electric Co |