1-321-802-5889

NSN 5925-00-930-2265

Overload Switch

About this product

Multipole-single actuator type body style, metal case material, double pole, double throw switch contact arrangement, fragility factor: moderately rugged.

Manufacturer part number THKMTKM11-836700 for national stock number 5925009302265.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-930-2265.

  • MPN or Model

    THKMTKM11-836700

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Multipole-single actuator type
  • Body Length
    Between 15.470 inches and 15.530 inches
  • Body Width
    Between 8.220 inches and 8.280 inches
  • Case Material
    Metal
  • Center To Center Distance Between Terminals Parallel To Length
    Between 11.590 inches and 11.650 inches
  • Center To Center Distance Between Terminals Parallel To Width
    Between 2.720 inches and 2.780 inches
  • Unthreaded Mounting Hole Diameter
    Between 0.340 inches and 0.400 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    Between 14.220 inches and 14.280 inches
  • Switch Contact Arrangement
    Double pole, double throw
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    Between 2.720 inches and 2.780 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    Between 0.350 inches and 0.410 inches
  • Mounting Surface To Terminal End Distance
    Between 10.970 inches and 11.030 inches
  • Pole Quantity
    3
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Features Provided
    Adjustable trip release
  • Maximum Continuous Load Current Rating Per Pole
    700.0 amperes ac all locations and 700.0 amperes dc all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    600.0 ac all locations and 125.0 dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    25000.0 ac all locations and 65000.0 dc all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Auxiliary Switch Function And Quantity
    1 control
  • Adjustable Trip Setting Current Range Per Pole In Amps
    +2100.0/+7000.0 ac all locations and +2100.0/+7000.0 dc all locations
  • Switch Location And Position Designation
    Internal at pole three
  • Inclosure Protection Type For Which Designed
    Hermetically sealed and weatherproof
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
  • Switch Terminal Type
    Wire lead
  • Switch Current Rating And Type In Amps
    6.0 ac and 0.5 dc
  • Switch Voltage Rating And Type In Volts
    600.0 ac and 125.0 dc
  • Frequency In Hertz
    60.0 all locations
  • Precious Material And Location
    Contacts silver
  • Precious Material
    Silver
  • Terminal Type And Quantity
    6 threaded stud
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-930-2265 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925009302265

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
THKMTKM11-836700 General Electric Co
9995643-2 U S Army Aviation And Missile
9995643-2 General Electric Co
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.