1-321-802-5889

NSN 5925-00-933-0172

Overload Switch

About this product

Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 1.

Manufacturer part number 2MC3-3-1 for national stock number 5925009330172.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-933-0172.

  • MPN or Model

    2MC3-3-1

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Single pole type
  • Bushing Length
    0.344 inches
  • Body Length
    1.781 inches
  • Body Width
    0.656 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    1.341 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Mounting Surface To Terminal End Distance
    1.669 inches
  • Pole Quantity
    1
  • Mounting Facility Type And Quantity
    1 threaded bushing
  • Storage Type
    General purpose warehouse
  • Thready Qty Per Inch (tpi)
    32
  • Maximum Continuous Load Current Rating Per Pole
    1.0 amperes dc single location
  • Operating Voltage Type And Rating Per Pole In Volts
    32.0 dc single location
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    2500.0 dc single location
  • Circuit Protection Type
    Overcurrent single location
  • Trip Release Method
    Magnetic single location
  • Trip Release Characteristic
    Time delay single location
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    135.0 single location
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole one
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip single location
  • Thread Size
    0.469 inches
  • Switch Location And Position Designation
    Internal at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    0.006 at 200 pct single location and 0.020 at 200 pct single location
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    7.0 ac and 4.0 dc
  • Switch Voltage Rating And Type In Volts
    130.0 ac and 28.0 dc
  • Thread Series Designator
    Uns
  • Terminal Type And Quantity
    2 screw
More from these suppliers
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-933-0172 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925009330172

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
2MC3-3-1 Sensata Technologies, Inc
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.