NSN 5925-00-946-2014
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number AM1510MG6-150-50VDC3 for national stock number 5925009462014.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-946-2014.
-
MPN or Model
AM1510MG6-150-50VDC3
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
3.719 inches -
Body Width
0.990 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.359 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
Unimproved open -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
150.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct single location and 0.550 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant and explosion resistant -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5925-00-104-8310 MPN AM12MG6-1-8-250VAC60C4Circuit Breaker
- 5925-00-185-9081 MPN AM1-Z22-081Circuit Breaker
- 5925-00-507-4826 MPN JA1-A3-20-3Circuit Breaker
- 5925-00-681-4951 MPN AM444MG6-3-115VAC400C15Circuit Breaker
- 5925-01-075-7144 MPN HE3-Z28-2Circuit Breaker
- 5925-01-092-4868 MPN CD3-Z117-2Circuit Breaker
- 5925-01-113-8272 MPN 3XAM17-15-120-55Circuit Breaker
- 5925-01-246-4515 MPN CF1-G8-DU-10-120/240-20Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-946-2014 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM1510MG6-150-50VDC3 | Eaton Corp |