NSN 5925-00-946-4550
Overload Switch
Used on 485l tacs,radio set (an/grc-201) weapon system.
Manufacturer part number 8525070-2 for national stock number 5925009464550.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-946-4550.
-
MPN or Model
8525070-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
3.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.471 inches -
Pole Quantity
4 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
8 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
4 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, three, and four linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 at 200 pct all locations and 80.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Criticality Code Justification
Feat -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5935-00-323-0909 MPN 252372-501Electrical Receptacle Connector
- 5950-00-646-0543 MPN B949354-1Reactor
- 5950-00-905-4099 MPN 8498818-506Radio Frequency Coil
- 5930-01-286-8923 MPN 8160305-5Push Switch
- 5905-00-925-2851 MPN 8771551-4Nonprecision Nonwire Wound Variable Resistor
- 5945-00-244-1568 MPN K843337-1Electromagnetic Relay
- 5930-00-141-3842 MPN 8488215-1Rotary Switch
- 5945-00-295-4733 MPN C746572REV2PT1Electromagnetic Relay
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-946-4550 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
8525070-2 | L-3 Communications Corporation |
8525070-2 | Lockheed Martin Corp |
73-108-2MG6 | Eaton Corp |
Stock Check