NSN 5925-00-965-8496
Overload Switch
Flush mtd on 11.750 in. By 8.000 in. Mtg centers.
Manufacturer part number ET1573E1 for national stock number 5925009658496.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-965-8496.
-
MPN or Model
ET1573E1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Overall Length
13.093 inches -
Overall Height
9.625 inches -
Overall Width
4.687 inches -
Case Material
Metal -
Pole Quantity
3 -
Arc Quenching Method
Deion -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Thread Size
0.250 inches -
Trip Release Duty Cycle
Continuous all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 at 150 pct all locations and 240.000 at 150 pct all locations and 3.000 at 500 pct all locations and 5.000 at 500 pct all locations -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations
More from these suppliers
- 5930-00-581-3779 MPN 498227Thermostatic Switch
- 5930-01-463-0179 MPN 8-42-11Switch Assembly
- 5945-01-477-7633 MPN 749505PC24Electromagnetic Relay
- 5930-01-494-1905 MPN 706378T1Sensitive Switch
- 5940-01-494-7434 MPN ETN6741Terminal Board
- 5930-01-435-5796 MPN 747074-K01Push Switch
- 5930-01-432-2145 MPN 8-34-9Switch Latch
- 5950-00-111-1970 MPN 702704DElectrical Coil
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-965-8496 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ET1573E1 | Spd Electrical Systems, Inc |