NSN 5925-00-981-2341
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number A15937-001 for national stock number 5925009812341.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-981-2341.
-
MPN or Model
A15937-001
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 3.709 inches and -
Body Width
Between 3.042 inches and 3.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and 1.041 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and 1.041 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Ultimate Trip Time Per Pole In Seconds
0.800 all locations and 3.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip first locationseries trip second locationrelay trip third location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 at 200 pct all locations and 1.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and general purpose and moisture resistant -
Frequency In Hertz
60.0 all locations -
Test Data Document
12436-a15136 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unc -
Terminal Type And Quantity
7 threaded stud
More from these suppliers
- 5935-00-167-4671 MPN 1-892-1Connector Adapter
- 5950-00-510-1754 MPN 650312-000Radio Frequency Coil
- 5950-00-646-0024 MPN 648807Audio Frequency Transformer
- 5940-00-680-9963 MPN 540021-020Feedthru Terminal
- 5935-01-135-0605 MPN 2117099-003Electrical Plug Connector
- 5935-01-396-4559 MPN 2215898-009Electrical Receptacle Connector
- 5950-00-203-1250 MPN 666231-907Radio Frequency Transformer
- 5935-01-391-8030 MPN 6011996-422Electrical Connector Backshell
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-981-2341 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
A15937-001 | Bae Systems Information And |
53-141-1MG3 | Eaton Corp |
A15136-001 | Bae Systems Information And |
53-160-1MG3 | Eaton Corp |