NSN 5925-00-982-6411
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number AM17-2-250-55-400 for national stock number 5925009826411.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-982-6411.
-
MPN or Model
AM17-2-250-55-400
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.190 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 200 pct single location and 9.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Explosion resistant -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
4.250 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5945-00-681-9736 MPN FM2-522XAXElectromagnetic Relay
- 5925-00-552-3433 MPN AM13MG3-50-115-6Circuit Breaker
- 5925-00-655-3893 MPN 53-161-1-MG3Circuit Breaker
- 5925-00-683-1440 MPN 3363-10-250-60-2Circuit Breaker
- 5925-00-920-6437 MPN AM17-0-1-115VAC60C54Circuit Breaker
- 5925-00-984-6125 MPN 3XAM1516MG3-5-416VAC400C13Circuit Breaker
- 5925-01-020-9501 MPN AM3-C3-A-15-2Circuit Breaker
- 5925-01-025-7007 MPN SM333-4-240-400-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-982-6411 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM17-2-250-55-400 | Eaton Corp |
AM17-2-250VAC400C55 | Eaton Corp |