NSN 5925-00-983-5297
Overload Switch
Multipole-single actuator type body style, plastic case material, 2 poles, maximum continuous load current rating per pole: 50.0 amperes ac all locations and 50.0 amperes dc all locations.
Manufacturer part number S451D855G05 for national stock number 5925009835297.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-983-5297.
-
MPN or Model
S451D855G05
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
6.500 inches -
Body Width
2.750 inches -
Body Height
3.375 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.562 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.625 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Boss Height
0.125 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations and 50.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac all locations and 10000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
24.000 at 200 pct all locations and 100.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
4 screw
More from these suppliers
- 4820-00-119-9584 MPN 9J968PC587-588Valve Disk
- 5905-00-332-9276 MPN 38J853ITEM24Resistor
- 5950-00-369-1553 MPN 1JH234PC19Power Transformer
- 5950-00-869-2672 MPN S575D899G02Power Transformer
- 5950-01-035-8411 MPN L339598Radio Frequency Coil
- 5950-01-115-5682 MPN 1491284Coil Spool
- 5930-01-172-9746 MPN 1173289Rotary Switch
- 5925-00-104-8537 MPN LA3200PTVCircuit Breaker Tripper
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-983-5297 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
S451D855G05 | Westinghouse Electric Corp |
EH2050V | Westinghouse Electric Corp |