About this product

Multipole-single actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.

Manufacturer part number 5667D81G30 for national stock number 5925009844510.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-984-4510.

  • MPN or Model

    5667D81G30

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Unit Weight (Est.)
    3.9 lb
  • Body Style
    Multipole-single actuator type
  • Body Length
    6.500 inches
  • Body Width
    4.125 inches
  • Body Height
    3.688 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    5.750 inches
  • Center To Center Distance Between Terminals Parallel To Width
    1.375 inches
  • Unthreaded Mounting Hole Diameter
    0.190 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    3.500 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    1.375 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    0.219 inches
  • Pole Quantity
    3
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Maximum Continuous Load Current Rating Per Pole
    125.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    240.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    10000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Thermal-magnetic all locations
  • Trip Release Characteristic
    Instantaneous all locations and time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Trip Delay Time In Seconds Per Rated Continuous Current
    90.000 at 200 pct all locations and 210.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    General purpose
  • Trip Release Ambient Tempurature Rating
    40.0 degrees celsius all locations
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    6 compression
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-984-4510 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925009844510

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
5667D81G30 Eaton Corporation
CA3125 Eaton Corporation
4990D77G30 Eaton Corporation
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.