NSN 5925-00-985-7935
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number PDLA-50 for national stock number 5925009857935.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-985-7935.
-
MPN or Model
PDLA-50
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Overall Length
3.156 inches -
Body Width
1.875 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.062 inches -
Unthreaded Mounting Hole Diameter
0.190 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.109 inches -
Pole Quantity
1 -
Arc Quenching Method
Air -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac single location and 50.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
900.0 ac single location and 900.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location -
Reset Method
Automatic -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 50.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Shockproof and vibrationproof -
Trip Release Ambient Tempurature Rating
77.0 degrees fahrenheit single location -
Frequency In Hertz
60.0 single location -
Unpackaged Unit Weight
4.000 ounces -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5930-00-261-6597 MPN M1120105282Thermostatic Switch
- 5930-00-719-3862 MPN 4286A10-95Thermostatic Switch
- 5930-00-958-3225 MPN AT4-2Sensitive Switch
- 5930-01-048-5422 MPN C6786-26Thermostatic Switch
- 5935-01-224-6543 MPN FMR-0415-80Electrical Receptacle Connector
- 5945-01-367-6469 MPN 7235-1-25Thermal Relay
- 5930-01-254-2842 MPN 21649Interlock Switch
- 5935-01-123-9904 MPN FE0207-70Electrical Receptacle Connector
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-985-7935 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
PDLA-50 | Sensata Technologies, Inc |
31027 | L-3 Communications Corporation |
Stock Check
![](/public/images/partscage_shelf3.png)