NSN 5925-00-993-4603
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 2 poles, thready qty per inch (tpi): 32.
Manufacturer part number 71-118-2MG6 for national stock number 5925009934603.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-993-4603.
-
MPN or Model
71-118-2MG6
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.530 inches -
Body Width
1.530 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.680 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc first location -
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip second location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct all locations and 0.500 at 200 pct all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5930-00-023-1924 MPN 21805Thermostatic Switch
- 5930-00-152-8601 MPN 1022016-17Thermostatic Switch
- 5935-00-237-6446 MPN M426865SUB3GP502Plug-in Electronic Components Socket
- 5950-00-435-8433 MPN 1792098-501Radio Frequency Coil
- 5985-00-976-3304 MPN 2188385-3Fixed Attenuator
- 5950-01-057-3231 MPN 8584076-7Reactor
- 5945-01-062-2697 MPN 8584089Motor Driven Relay
- 5950-01-155-7080 MPN 746916-159Radio Frequency Coil
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-993-4603 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
71-118-2MG6 | Eaton Corp |
8983056-1 | L-3 Communications Corporation |