NSN 5925-01-004-6307
Overload Switch
Single pole type body style, metal case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number HE3-C3-0-75-240VAC400HZ2 for national stock number 5925010046307.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-004-6307.
-
MPN or Model
HE3-C3-0-75-240VAC400HZ2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
Between 0.365 inches and 0.385 inches -
Body Length
Between 1.552 inches and 1.572 inches -
Body Width
Between 1.844 inches and 1.906 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.865 inches and 0.885 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.615 inches and 0.635 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.690 inches and 1.710 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
Thd bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
75.0 milliamperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
0.700 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 at 150 pct all locations and 0.150 at 200 pct all locations and 0.035 at 300 pct all locations and 0.004 at 1000 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and explosion proof and fungus resistant and moisture resistant and vibrationproof -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook
More from these suppliers
- 5925-00-035-4126 MPN 70-183-6MG3Circuit Breaker
- 5925-00-055-9372 MPN 3XAM17-2-5-208-60-54Circuit Breaker
- 5925-00-081-4575 MPN AM17-20-120VAC400-55Circuit Breaker
- 5925-00-170-4083 MPN GB3-A3-1.75-1Circuit Breaker
- 5925-00-491-8983 MPN JA1-C2-5-2Circuit Breaker
- 5925-00-522-2557 MPN AM1-Z10-3-5Circuit Breaker
- 5925-00-724-4388 MPN AM12MG6-15-125-60-5Circuit Breaker
- 5925-00-959-6075 MPN SM3-10-50VDC57Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-004-6307 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
HE3-C3-0-75-240VAC400HZ2 | Eaton Corp |