NSN 5925-01-026-5842
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number GC885DW2 for national stock number 5925010265842.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-026-5842.
-
MPN or Model
GC885DW2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Bushing Length
0.375 inches -
Body Length
1.381 inches -
Body Width
0.531 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.531 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.669 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.438 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Vibrationproof -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
62.0 grams -
Thread Series Designator
Un -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5985-00-061-9577 MPN 121SCAV127-5Waveguide Assembly
- 1560-00-098-0971 MPN 89WM2100-1Fitting Asy
- 5935-00-103-4177 MPN GJ802R1-8Tip Jack
- 5985-00-201-5061 MPN 128SCAV744-1Waveguide Adapter
- 1560-00-276-8806 MPN 123AMM12127-1Link Assembly
- 5975-00-284-5827 MPN GJ800V1Junction Box
- 5935-00-355-4663 MPN GC810NP1AElectrical Plug Connector
- 5905-00-434-0815 MPN 1128SCSEA742-1Resistor Module
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-026-5842 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
GC885DW2 | Northrop Grumman Systems Corporation |
6TC12-2 | Sensata Technologies, Inc |