NSN 5925-01-029-3311
Overload Switch
Multipole-single actuator type body style, plastic case material, at 12 oclock nonturn device location, switch contact arrangement: single pole, double throw.
Manufacturer part number 3179574-0018 for national stock number 5925010293311.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-029-3311.
-
MPN or Model
3179574-0018
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.280 inches and 0.380 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
0.687 inches -
Nonturn Device Location
At 12 oclock -
Nonturn Device Radius
0.625 inches -
Nonturn Device Diameter
Between 0.180 inches and 0.300 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Switch Location And Position Designation
Internal at pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 at 200 pct all locations and 6.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and vibration resistant and moisture resistant and shock resistant and salt spray proof -
Switch Terminal Type
Pin -
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc -
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Test Data Document
10001-3179574 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5935-00-080-8456 MPN 720636Electrical Receptacle Connector
- 5905-00-106-0152 MPN 63A76A1006-9Wire Wound Fixed Resistor
- 5940-00-178-0936 MPN 319322PC18Lug Terminal
- 5945-00-201-7834 MPN 1756222Thermal Flasher
- 5975-00-284-9340 MPN 329108-145Stuffing Tube Packing Nut
- 5985-00-431-6130 MPN 2536482Waveguide Assembly
- 5905-00-470-5062 MPN 2552855Film Fixed Resistor Network
- 5935-00-498-4313 MPN 2678137-14Electrical Receptacle Connector Body
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-029-3311 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3179574-0018 | Naval Sea Systems Command |
3179574-18 | Navair And Navsea Managed |
3179574-18 | Lockheed Martin Librascope |
3179574-0018 | Naval Sea Systems Command |
3179574-18 | Navair And Navsea Managed |
3179574-18 | Lockheed Martin Librascope |
3179574-0018 | Naval Sea Systems Command |
3179574-18 | Navair And Navsea Managed |
3179574-18 | Lockheed Martin Librascope |
3179574-0018 | Naval Sea Systems Command |
3179574-18 | Navair And Navsea Managed |
3179574-18 | Lockheed Martin Librascope |
3179574-0018 | Naval Sea Systems Command |
3179574-18 | Navair And Navsea Managed |
3179574-18 | Lockheed Martin Librascope |
Stock Check