NSN 5925-01-034-1801
Overload Switch
White toggle levers.
Manufacturer part number M55629-10-080 for national stock number 5925010341801.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-034-1801.
-
MPN or Model
M55629-10-080
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-multiple actuator type -
Bushing Length
0.130 inches -
Body Length
2.000 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.560 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Mounting Surface To Terminal End Distance
2.032 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
85.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip w/auxiliary load terminal all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 150 pct all locations -
Switch Terminal Type
Quick disconnect, male -
Switch Current Rating And Type In Amps
10.0 ac -
Switch Voltage Rating And Type In Volts
240.0 ac -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5935-00-004-7675 MPN M83723/24R2015NElectrical Plug Connector
- 5905-00-006-7128 MPN MIL-R-39008/5Composition Fixed Resistor
- 5935-00-011-7884 MPN MIL-C-26482Electrical Receptacle Connector
- 5905-00-012-0712 MPN RNR55H2742FRFilm Fixed Resistor
- 5905-00-022-5663 MPN RT24C2X102FSNonprecision Wire Wound Variable Resistor
- 5935-00-036-8555 MPN MILC28748-3Electrical Plug Connector
- 5905-00-039-7169 MPN MIL-R-39009/1Inductive Wire Wound Fixed Resistor
- 5905-00-043-1197 MPN MIL-R-18546/2Inductive Wire Wound Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-034-1801 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629-10-080 | Military Specifications |