Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 50.0 amperes ac all locations and 50.0 amperes ac all locations and 50.0 amperes ac all locations.
Manufacturer part number 7905172-00 for national stock number 5925010433460.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-043-3460.
-
MPN or Model
7905172-00
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
1.4 lb -
Body Style
Multipole-multiple actuator type -
Body Length
Between 3.709 inches and 3.729 inches -
Body Width
Between 3.042 inches and 3.062 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 3.053 inches and 3.073 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 1.021 inches and 1.041 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.740 inches and 2.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 1.021 inches and 1.041 inches -
Boss Height
Between 0.146 inches and 0.166 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 threaded hole -
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations and 50.0 amperes ac all locations and 50.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 240.0 ac all locations and 115.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal all locations and thermal all locations and magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-200-9310 MPN AM1-A3-A-30-3Circuit Breaker
- 5925-00-243-7128 MPN SM3-15-50VDC57Circuit Breaker
- 5925-00-265-2275 MPN 3363SMG4-20-45Circuit Breaker
- 5925-00-449-3622 MPN 79-106-7Circuit Breaker
- 5925-00-542-8778 MPN AM13MG3-1-5-117VAC60C4Circuit Breaker
- 5925-00-848-7917 MPN PCB672-2-5-6Circuit Breaker
- 5925-01-037-6878 MPN HE2A3-8-2Circuit Breaker
- 5925-01-045-5145 MPN AM1-B2-A-15-2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-043-3460 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
7905172-00 | Lockheed Martin Corporation |
53-216-1 | Eaton Corp |