NSN 5925-01-045-7172
Overload Switch
Multipole-single actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number AP-MIL-112-1-7-2-501 for national stock number 5925010457172.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-045-7172.
-
MPN or Model
AP-MIL-112-1-7-2-501
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Thread Pitch Diameters
+0.3503/+0.3537 inches -
Body Style
Multipole-single actuator type -
Bushing Length
0.380 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Center To Center Distance Between Terminals Parallel To Width
0.687 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac all locations and 500.0 milliamperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct all locations and 9.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed and moisture resistant and vibration resistant and fungus resistant and shock resistant and salt spray proof -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
150.0 grams -
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook -
Specification Data
81349-mil-prf-39019/5 government specification
More from these suppliers
- 5950-00-087-7300 MPN 544-9715-002Radio Frequency Transformer
- 5950-00-118-8135 MPN 278-2120-010Radio Frequency Transformer
- 5905-00-226-3564 MPN 705-1006-000Film Fixed Resistor
- 5950-00-228-7555 MPN 571-0800-40Radio Frequency Transformer
- 5950-00-301-4494 MPN 506-1572-003Radio Frequency Coil
- 5935-00-303-0713 MPN 504-8463-002Electrical Connector Shell
- 5930-00-369-8287 MPN 269-1270-000Rotary Switch Section
- 5930-00-433-7261 MPN 502-5494-002Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-045-7172 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AP-MIL-112-1-7-2-501 | Sensata Technologies Maryland, Inc |
SM333-0-5-240VAC400C1 | Eaton Corp |
M39019/05-210 | Military Specifications |
MIL-PRF-39019/5 | Military Specifications |
260-4039-150 | Rockwell Collins, Inc. |
AP112-020-231-0210 | Sensata Technologies Maryland, Inc |
AP112-1-62-501 | Sensata Technologies Maryland, Inc |
HB3Z1-18 | Eaton Corp |
HE3Z6-18 | Eaton Corp |
HE3A3-0-5-1 | Eaton Corp |
M39019/05-18 | Military Specifications |
MIL-C-39019/5 | Military Specifications |
MILC39019+5B20 | Military Specifications |
M39019-5-20 | Military Specifications |