NSN 5925-01-046-6903
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 260-4008-550 for national stock number 5925010466903.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-046-6903.
-
MPN or Model
260-4008-550
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Single pole type -
Body Length
2.500 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.940 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.150 inches -
Mounting Surface To Terminal End Distance
2.475 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 at 200 pct single location and 1.200 at 200 pct single location -
Inclosure Protection Type For Which Designed
Fungus resistant -
Unpackaged Unit Weight
4.250 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5985-00-020-7956 MPN 013-1331-020Radio Frequency Transmission Line Section
- 5930-00-116-6573 MPN 269-2613-140Rotary Switch Section
- 5935-00-132-2675 MPN 372-5883-010Electrical Plug Connector
- 5905-00-141-1116 MPN 745-1383-000Composition Fixed Resistor
- 5905-00-200-9295 MPN 705-7262-000Film Fixed Resistor
- 5905-00-233-4033 MPN 705-1475-050Film Fixed Resistor
- 5930-00-413-0594 MPN 771-1828-001Switch Actuator Adapter
- 5950-00-504-7621 MPN 288-1089-00Electromagnetic Component Core
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-046-6903 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
260-4008-550 | Rockwell Collins, Inc. |
260-4008-550 | Alcatel-lucent Holdings Inc. |
2604008550 | Sensata Technologies Maryland, Inc |
APL1-533-550 | Sensata Technologies Maryland, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)