NSN 5925-01-051-3696
Overload Switch
Multipole-single actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 40.0 amperes ac all locations.
Manufacturer part number Q0340VH for national stock number 5925010513696.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-051-3696.
-
MPN or Model
Q0340VH
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
3 lb -
Body Style
Multipole-single actuator type -
Body Length
3.000 inches -
Body Width
2.230 inches -
Body Height
2.580 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Width
0.740 inches -
Boss Height
0.250 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
3 terminal -
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
240.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
3 clip and 3 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-051-3696 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
Q0340VH | Schneider Electric Usa, Inc. |
Q1-340-VH | Square D Co |
Q0340VH | Square D Co |
Stock Check
![](/public/images/partscage_shelf3.png)