NSN 5925-01-061-9171
Overload Switch
Plastic case material, moderately rugged fragility factor, 2 poles, arc quenching method: magnetic blowout.
Manufacturer part number M55629/3-122 for national stock number 5925010619171.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-061-9171.
-
MPN or Model
M55629/3-122
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.8 lb -
Body Length
2.510 inches -
Body Width
Between 1.437 inches and 1.563 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.719 inches and 0.781 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.719 inches and 0.781 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.553 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Frequency In Hertz
60.0 all locations -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud -
Specification Data
81349-mil-c-55629/3 government specification
More from these suppliers
- 5905-00-006-5428 MPN RER65F3011RInductive Wire Wound Fixed Resistor
- 5905-00-006-5569 MPN RLR05C752GMFilm Fixed Resistor
- 5905-00-007-7236 MPN RB52CE12700FNoninductive Wire Wound Fixed Resistor
- 5905-00-008-6824 MPN RNR60G4992FPFilm Fixed Resistor
- 5905-00-009-6536 MPN RNC70H4122FSFilm Fixed Resistor
- 5905-00-013-9444 MPN RB18CE68502BNoninductive Wire Wound Fixed Resistor
- 5905-00-018-0950 MPN RW23V301Inductive Wire Wound Fixed Resistor
- 5905-00-024-0598 MPN RNC65J1000BMFilm Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-061-9171 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
M55629/3-122 | Military Specifications |
MIL-PRF-55629/3 | Military Specifications |
7906263-121 | Lockheed Martin Corporation |
M55629/3-122 | Military Specifications |
MIL-PRF-55629/3 | Military Specifications |
7906263-121 | Lockheed Martin Corporation |