NSN 5925-01-066-3738
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number APL-1-1R0-55629/2-106 for national stock number 5925010663738.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-066-3738.
-
MPN or Model
APL-1-1R0-55629/2-106
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.2 lb -
Body Style
Single pole type -
Body Length
2.510 inches -
Body Width
Between 0.730 inches and 0.780 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.660 inches and 1.960 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.046 inches and 2.078 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.109 inches and 0.171 inches -
Mounting Surface To Terminal End Distance
2.800 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct single location and 8.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud -
Specification Data
81349-mil-c-55629/2 government specification
More from these suppliers
- 5945-00-615-7175 MPN FM1-522XAX115V60HZ5SECElectromagnetic Relay
- 5925-00-172-3049 MPN 3XAM1516MG3-20-250VAC60C3Circuit Breaker
- 5925-00-306-2818 MPN AM333MG6-35-250VAC400C14Circuit Breaker
- 5925-00-306-2823 MPN AM12MG6-2-21Circuit Breaker
- 5925-00-587-4154 MPN XAM33MG3-1-154-1Circuit Breaker
- 5925-00-677-8320 MPN X0411 TSHKMG4-7-32VDC-3Circuit Breaker
- 5925-00-761-2143 MPN 79-14621Circuit Breaker
- 5925-00-862-6719 MPN AM333MG6-5-25-25-250-60Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-066-3738 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL-1-1R0-55629/2-106 | Sensata Technologies Maryland, Inc |
76-639-27MG6 | Eaton Corp |
M55629/2-106 | Military Specifications |
MIL-C-55629/2 | Military Specifications |
APL1R-778-27 | Sensata Technologies Maryland, Inc |
APL1-1REC4-M55629/2-106 | Sensata Technologies, Inc |